Skip Preloader

LC2K1210P7

TeSys K reversing contactor – 3P – AC-3 <= 440 V 12 A – 1 NO – 230 V AC coil

  • Tag:
  • Weight:
    0.39 kg
  • Dimensions:
    9.1 × 6.4 × 6 cm

Description

range
TeSys
product name
TeSys K
product or component type
Reversing contactor
device short name
LC2K
device application
Control
contactor application
Resistive load
Motor control
utilization category
AC-1
AC-3
AC-4
device presentation
Preassembled with reversing power busbar
poles description
3P
power pole contact composition
3 NO
[Ue] rated operational voltage
Power circuit: 690 V AC 50/60 Hz
Signalling circuit: <= 690 V AC 50/60 Hz
[Ie] rated operational current
20 A (at <50 °C) at <= 440 V AC AC-1 for power circuit
16 A (at <70 °C) at 690 V AC AC-1 for power circuit
12 A at <= 440 V AC AC-3 for power circuit
motor power kW
4 kW at 480 V AC 50/60 Hz
4 kW at 500…600 V AC 50/60 Hz
4 kW at 660…690 V AC 50/60 Hz
3 kW at 220…230 V AC 50/60 Hz
5.5 kW at 380…415 V AC 50/60 Hz
5.5 kW at 440 V AC 50/60 Hz
control circuit type
AC at 50/60 Hz
[Uc] control circuit voltage
230 V AC 50/60 Hz
auxiliary contact composition
1 NO
[Uimp] rated impulse withstand voltage
8 kV
overvoltage category
III
[Ith] conventional free air thermal current
20 A (at 50 °C) for power circuit
10 A (at 50 °C) for signaling circuit
Irms rated making capacity
144 A at 690 V AC for power circuit conforming to NF C 63-110
144 A at 690 V AC for power circuit conforming to IEC 60947
110 A AC for signaling circuit conforming to IEC 60947
rated breaking capacity
110 A at 440 V conforming to IEC 60947
80 A at 500 V conforming to IEC 60947
70 A at 660…690 V conforming to IEC 60947
[Icw] rated short-time withstand current
115 A 50 °C – 1 s for power circuit
105 A 50 °C – 5 s for power circuit
100 A 50 °C – 10 s for power circuit
75 A 50 °C – 30 s for power circuit
55 A 50 °C – 1 min for power circuit
50 A 50 °C – 3 min for power circuit
80 A – 1 s for signaling circuit
90 A – 500 ms for signaling circuit
110 A – 100 ms for signaling circuit
25 A 50 °C – >= 15 min for power circuit
associated fuse rating
25 A gG at <= 440 V for power circuit
25 A aM for power circuit
10 A gG for signaling circuit conforming to IEC 60947
10 A gG for signaling circuit conforming to VDE 0660
average impedance
3 mOhm – Ith 20 A 50 Hz for power circuit
[Ui] rated insulation voltage
Power circuit: 600 V conforming to UL 508
Power circuit: 690 V conforming to IEC 60947-4-1
Signaling circuit: 690 V conforming to IEC 60947-4-1
Signaling circuit: 690 V conforming to IEC 60947-5-1
Signaling circuit: 600 V conforming to UL 508
Power circuit: 600 V conforming to CSA C22.2 No 14
Signaling circuit: 600 V conforming to CSA C22.2 No 14
electrical durability
0.3 Mcycles 20 A AC-1 at Ue <= 440 V
1.3 Mcycles 12 A AC-3 at Ue <= 440 V
interlocking type
Mechanical
mounting support
Plate
Rail
standards
BS 5424
IEC 60947
NF C 63-110
VDE 0660
product certifications
CSA
UL
connections – terminals
Screw clamp terminals 1 cable(s) 1.5…4 mm²solid
Screw clamp terminals 1 cable(s) 0.75…4 mm²flexible without cable end
Screw clamp terminals 1 cable(s) 0.34…2.5 mm²flexible with cable end
Screw clamp terminals 2 cable(s) 1.5…4 mm²solid
Screw clamp terminals 2 cable(s) 0.75…4 mm²flexible without cable end
Screw clamp terminals 2 cable(s) 0.34…1.5 mm²flexible with cable end
tightening torque
1.3 N.m – on screw clamp terminals – with screwdriver Philips No 2
1.3 N.m – on screw clamp terminals – with screwdriver flat Ø 6 mm
operating time
10…20 ms coil energization and NO closing
10…20 ms coil de-energization and NO opening
safety reliability level
B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
mechanical durability
5 M cycles
maximum operating rate
3600 cyc/h

Additional information

  • Tag:
  • Weight
    0.39 kg
  • Dimensions
    9.1 × 6.4 × 6 cm

Reviews (0)

Be the first to review “LC2K1210P7”